Parameter | from | to | steps |
---|---|---|---|
Total diameter | 7.50 mm | 12.00 mm | 0.01 mm |
Base curve | 6.00 mm | 9.00 mm | 0.01 mm |
Sphere | -40.00 dpt | +40.00 dpt | 0.01 dpt |
Eccentricity | 0.10 | 0.90 | 0.01 |
Application | |
---|---|
Indication | |
Correction type | |
Lens Type | |
Designed by | SwissLens |
The optimal fluorescein pattern shows a small fluor lake in the center and a larger fluor ring in the periphery (env. 0.75 mm).
Vertical movement should be around 1 mm. In case of too much movement, decrease both central back curves (r0fl and r0st) with -0.10 mm. In case of low riders, increase both central back curves (r0fl and r0st) with +0.10 mm or in case the upper lid is pushing the lens down, increase the total diameter ØT.
In case of high riders, decrease total diameter ØT
In case of instable stabilisation and/or high riders, increase the prism to 2.0 cm/m.
WARNING: the stabilisation prism induce an optical prism. This should be adjusted on both eyes.
Features | Optimum Infinite | Boston XO | Optimum Comfort | Boston EO | Optimum Classic | Boston ES | Contaperm F2 low |
---|---|---|---|---|---|---|---|
DK Fatt ISO 9913-1 | 180*/ 135** | 100*/75** | 65*/49** | 58*/44** | 26*/19.5** | 18*/15** | 11*/8** |
Manufacturer | Contamac | Polymertechnology | Contamac | Polymertechnology | Contamac | Polymertechnology | Contamac |
Wettability angle | 49° (2) | 6° (3) | 49° (2) | 12° (3) | 52° (2) | 19° (2) | |
Hardness (4) | 81 | 79.9 | 79 | 83 | 83 | 85.4 | 83 |
Refractive index | 1.44 | 1.415 | 1.437 | 1.429 | 1.45 | 1.443 | 1.46 |
Handling tint | blue red green clear | blue red green lila | blue green | blue | blue green | blue green | blue green clear |
UV | √ | √ | √ | √ | √ | √ | √ |
Durability | ++ | ++ | +++ | ++ | +++ | +++ | +++ |
Resistance deformation (5) | ++ | ++ | ++ | ++ | +++ | +++ | ++ |
Long term wearing | +++ | +++ | ++ | ++ | + | + | + |
Tear film with lipid | + | + | ++ | ++ | ++ | +++ | ++ |
Tear film with protein | + | + | ++ | ++ | ++ | +++ | ++ |
Wettability | ++ | ++ | +++ | ++ | ++ | +++ | +++ |
* ×10-11 (cm2/sec) [ml 02/(ml × mm Hg)]
** ×10-11 (cm2/sec) [ml 02/(ml × hPa)]
2 Wettability angle = CLMA method
3 Receding contact angle (DCA)
4 Shore D
5 Corneal astigmatism
More information about the product features (Article by Boston Materials)
Default material: Optimum Classic Blue
These materials are in conformity with the standard ISO 10993-1 defining the biocompatibility of materials.
SwissLens manufacturing process warrants this biocompatibility even after the manufacturing process, in particular without adding polish material. This standard is required by the quality assurance system of SwissLens.
Material Training with Martin Conway from Contamac
© 2020 ALL rIGHTS RESERVED
SwissLens - SIMPLICITY WITHOUT LIMITS
We are currently in annual team meeting.
Our phonecall line is currently closed, We apologize and try to do our best to come back as soon as possible.
Customer service email : lens.order@swisslens.ch