Parameter | from | to | steps |
---|---|---|---|
Total diameter | 10.00 mm | 12.00 mm | 0.01 mm |
Base curve | 6.00 mm | 12.00 mm | 0.01 mm |
Sphere | -40.00 dpt | +40.00 dpt | 0.01 dpt |
Application | |
---|---|
Indication | |
Correction type | |
Lens Type | |
Designed by | SwissLens |
If the adaptation is not satisfactory, try Orbiflex SxS for fine tuning
Order the definitive contact lens on line using the form “Back surface design”
Determine if the vision is alternate (change of optic zones by translation) or simultaneous (change of optic zones by visual cortex selection):
Requirements | Bifocal Bf | Simple progressive Sp |
---|---|---|
Myopia Addition < 1.75 dpt | √ | |
Myopia: Addition ≥ 1.75 dpt | √ | |
Priority in distance vision | √ | |
Priority in near vision | dominant eye | non dominant eye |
Good contrast | √ |
Recommendations for the 1st choice: standard pupil (3.50–4.00 mm) with normal lighting
Bifocal Bf | Bifocal Bf | Simple progressive Sp | Simple progressive Sp | |
---|---|---|---|---|
Position | Centre near (CN) | Centre Distance (CD) | Centre near (CN) | Centre Distance (CD) |
Dominant eye | 2.25 | 3.75 | 2.50 | 4.00 |
Non-dominant eye | 2.75 | 3.25 | 3.00 | 3.50 |
Undefined | 2.50 | 3.50 | 2.75 | 3.75 |
For non standard pupil size or for distance/near preference, fit the Zoc in steps of 0.25 mm
Features | Optimum Infinite | Boston XO | Optimum Comfort | Boston EO | Optimum Classic | Boston ES | Contaperm F2 low |
---|---|---|---|---|---|---|---|
DK Fatt ISO 9913-1 | 180*/ 135** | 100*/75** | 65*/49** | 58*/44** | 26*/19.5** | 18*/15** | 11*/8** |
Manufacturer | Contamac | Polymertechnology | Contamac | Polymertechnology | Contamac | Polymertechnology | Contamac |
Wettability angle | 49° (2) | 6° (3) | 49° (2) | 12° (3) | 52° (2) | 19° (2) | |
Hardness (4) | 81 | 79.9 | 79 | 83 | 83 | 85.4 | 83 |
Refractive index | 1.44 | 1.415 | 1.437 | 1.429 | 1.45 | 1.443 | 1.46 |
Handling tint | blue red green clear | blue red green lila | blue green | blue | blue green | blue green | blue green clear |
UV | √ | √ | √ | √ | √ | √ | √ |
Durability | ++ | ++ | +++ | ++ | +++ | +++ | +++ |
Resistance deformation (5) | ++ | ++ | ++ | ++ | +++ | +++ | ++ |
Long term wearing | +++ | +++ | ++ | ++ | + | + | + |
Tear film with lipid | + | + | ++ | ++ | ++ | +++ | ++ |
Tear film with protein | + | + | ++ | ++ | ++ | +++ | ++ |
Wettability | ++ | ++ | +++ | ++ | ++ | +++ | +++ |
* ×10-11 (cm2/sec) [ml 02/(ml × mm Hg)]
** ×10-11 (cm2/sec) [ml 02/(ml × hPa)]
2 Wettability angle = CLMA method
3 Receding contact angle (DCA)
4 Shore D
5 Corneal astigmatism
More information about the product features (Article by Boston Materials)
Default material: Optimum Classic Blue
These materials are in conformity with the standard ISO 10993-1 defining the biocompatibility of materials.
SwissLens manufacturing process warrants this biocompatibility even after the manufacturing process, in particular without adding polish material. This standard is required by the quality assurance system of SwissLens.
Material Training with Martin Conway from Contamac
© 2020 ALL rIGHTS RESERVED
SwissLens - SIMPLICITY WITHOUT LIMITS
We are currently in annual team meeting.
Our phonecall line is currently closed, We apologize and try to do our best to come back as soon as possible.
Customer service email : lens.order@swisslens.ch